HOME | REACH US  
 



.com .net .org .info .mobi
.biz .us .co.uk .in
.eu .ws .bz .cc .tv Etc.
Domain Names

Website Development
Web Hosting
Email Hosting
Digital Certificate
Etc.

@ Best Prices From

www.DomainsUAE.com
Chemical oxygen demand
   
Google
 
Web libraryoflibrary.com

In environmental chemistry, the chemical oxygen demand (COD) test is commonly used to indirectly measure the amount of organic compounds in water. Most applications of COD determine the amount of organic pollutants found in surface water (e.g. lakes and rivers), making COD a useful measure of water quality. It is expressed in milligrams per liter (mg/L), which indicates the mass of oxygen consumed per liter of solution. Older references may express the units as parts per million (ppm).

Contents

Overview

The basis for the COD test is that nearly all organic compounds can be fully oxidized to carbon dioxide with a strong oxidizing agent under acidic conditions. The amount of oxygen required to oxidize an organic compound to carbon dioxide, ammonia, and water is given by:

\mbox{C}_n\mbox{H}_a\mbox{O}_b\mbox{N}_c + \left( n + \frac{a}{4} - \frac{b}{2} - \frac{3}{4}c \right)\mbox{O}_2 \rightarrow n\mbox{CO}_2 + \left( \frac{a}{2} - \frac{3}{2}c \right)\mbox{H}_2\mbox{O} + c\mbox{NH}_3

This expression does not include the oxygen demand caused by the oxidation of ammonia into nitrate. The process of ammonia being converted into nitrate is referred to as nitrification. The following is the correct equation for the oxidation of ammonia into nitrate.

\mbox{N}\mbox{H}_3 + 2\mbox{O}_2 \rightarrow \mbox{N}\mbox{O}_3^- + \mbox{H}_3\mbox{O}^+

The second equation should be applied after the first one to include oxidation due to nitrification if the oxygen demand from nitrification must be known. Dichromate does not oxidize ammonia into nitrate, so this nitrification can be safely ignored in the standard chemical oxygen demand test.

The International Organization for Standardization describes a standard method for measuring chemical oxygen demand in ISO 6060 [1].

History

For many years, the strong oxidizing agent potassium permanganate (KMnO4) was used for measuring chemical oxygen demand. Measurements were called oxygen consumed from permanganate, rather than the oxygen demand of organic substances. Potassium permanaganate's effectiveness at oxidizing organic compounds varied widely, and in many cases biochemical oxygen demand (BOD) measurements were often much greater than results from COD measurements. This indicated that potassium permanganate was not able to effectively oxidize all organic compounds in water, rendering it a relatively poor oxidizing agent for determining COD.

Since then, other oxidizing agents such as ceric sulfate, potassium iodate, and potassium dichromate have been used to determine COD. Of these, potassium dichromate (K2Cr2O7) has been shown to be the most effective: it is relatively cheap, easy to purify, and is able to nearly completely oxidize almost all organic compounds.

Using potassium dichromate

Potassium dichromate is a strong oxidizing agent under acidic conditions. (Acidity is usually achieved by the addition of sulfuric acid.) The reaction of potassium dichromate with organic compounds is given by:

\mathrm{C_nH_aO_bN_c\ +\ dCr_2O_7^{2-}\ +\ (8d\ +\ c)H^+ \rightarrow nCO_2\ +\ \frac {a + 8d - 3c}{2}H_2O\ +\ cNH_4^+\ +\ 2dCr^{3+}}

where d = 2n/3 + a/6 - b/3 - c/2. Most commonly, a 0.25 N solution of potassium dichromate is used for COD determination, although for samples with COD below 50 mg/L, a lower concentration of potassium dichromate is preferred.

In the process of oxidizing the organic substances found in the water sample, potassium dichromate is reduced (since in all redox reactions, one reagent is oxidized and the other is reduced), forming Cr3+. The amount of Cr3+ is determined after oxidization is complete, and is used as an indirect measure of the organic contents of the water sample.

Blanks

Because COD measures the oxygen demand of organic compounds in a sample of water, it is important that no outside organic material be accidentally added to the sample to be measured. To control for this, a so-called blank sample is required in the determination of COD (and BOD, for that matter). A blank sample is created by adding all reagents (e.g. acid and oxidizing agent) to a volume of distilled water. COD is measured for both the water and blank samples, and the two are compared. The oxygen demand in the blank sample is subtracted from the COD for the original sample to ensure a true measurement of organic matter.

Measurement of excess

For all organic matter to be completely oxidized, an excess amount of potassium dichromate (or any oxidizing agent) must be present. Once oxidation is complete, the amount of excess potassium dichromate must be measured to ensure that the amount of Cr3+ can be determined with accuracy. To do so, the excess potassium dichromate is titrated with ferrous ammonium sulfate (FAS) until all of the excess oxidizing agent has been reduced to Cr3+. Typically, the oxidation-reduction indicator Ferroin is added during this titration step as well. Once all the excess dichromate has been reduced, the Ferroin indicator changes from blue-green to reddish-brown. The amount of ferrous ammonium sulfate added is equivalent to the amount of excess potassium dichromate added to the original sample.

Preparation Ferroin Indicator reagent

A solution of 1.485 g 1,10-phenanthroline monohydrate is added to a solution of 695 mg FeSO4·7H2O in water, and the resulting red solution is diluted to 100 mL.

Calculations

The following formula is used to calculate COD:

COD = \frac{8000 (b - s)n}{sample\ volume}

where b is the volume of FAS used in the blank sample, s is the volume of FAS in the original sample, and n is the normality of FAS. If milliliters are used consistently for volume measurements, the result of the COD calculation is given in mg/L.

The COD can also be estimated from the concentration of oxidizable compound in the sample, based on its stoichiometric reaction with oxygen to yield CO2 (assume all C goes to CO2), H2O (assume all H goes to H2O), and NH3 (assume all N goes to NH3), using the following formula:

COD = (C/FW)(RMO)(32)
Where C = Concentration of oxidizable compound in the sample,
FW = Formula weight of the oxidizable compound in the sample,
RMO = Ratio of the # of moles of oxygen to # of moles of oxidizable compound in their reaction to CO2, water, and ammonia

For example, if a sample has 500 wppm of phenol:

C6H5OH + 7O2 ? 6CO2 + 3H2O
COD = (500/94)(7)(32) = 1191 wppm

Inorganic interference

Some samples of water contain high levels of oxidizable inorganic materials which may interfere with the determination of COD. Because of its high concentration in most wastewater, chloride is often the most serious source of interference. Its reaction with potassium dichromate follows the equation:

\mathrm{6Cl^- + Cr_2O_7^{2-} + 14H^+ \rightarrow 3Cl_2 + 2Cr^{3+} + 7H_2O}

Prior to the addition of other reagents, mercuric sulfate can be added to the sample to eliminate chloride interference.

The following table lists a number of other inorganic substances that may cause interference. The table also lists chemicals that may be used to eliminate such interference, and the compounds formed when the inorganic molecule is eliminated.

Inorganic molecule Eliminated by Elimination forms
Chloride Mercuric sulfate Mercuric chloride complex
Nitrite Sulfamic acid N2 gas
Ferrous iron - -
Sulfides - -

Government regulation

Many governments impose strict regulations regarding the maximum chemical oxygen demand allowed in wastewater before they can be returned to the environment. For example, in Switzerland, a maximum oxygen demand between 200 and 1000 mg/L must be reached before wastewater or industrial water can be returned to the environment [2].

See also

References

  • Clair N. Sawyer, Perry L. McCarty, Gene F. Parkin (2003). Chemistry for Environmental Engineering and Science (5th ed.). New York: McGraw-Hill. ISBN 0-07-248066-1. 
  • Lenore S. Clescerl, Arnold E. Greenberg, Andrew D. Eaton. Standard Methods for Examination of Water & Wastewater (20th ed.). Washington, DC: American Public Health Association. ISBN 0-87553-235-7. 

External links



Index Of Related Pages




All pages | Previous page (Chelsia wilson) | Next page (Chemiré)

Chemical oxygen demandChemical oxygen generator
Chemical oxygen iodine laserChemical patent
Chemical peel
Chemical physicsChemical plant
Chemical pneumonitisChemical polarity
Chemical potential
Chemical process
Chemical process modeling
Chemical property
Chemical reaction
Chemical reaction (disambiguation)
Chemical reactor
Chemical regulation
Chemical safety signs
Chemical sensitivity
Chemical shift
Chemical similarity
Chemical spaceChemical speciesChemical specificity
Chemical stabilityChemical state
Chemical structure
Chemical substance
Chemical symbol
Chemical synapse
Chemical synthesis
Chemical table fileChemical tankChemical tanker
Chemical test
Chemical tests in mushroom identification
Chemical thermodynamicsChemical toilet
Chemical transformation
Chemical transport modelChemical transport reaction
Chemical trapChemical vapor depositionChemical vapor deposition of diamond
Chemical vapor infiltration
Chemical warfare
Chemical waste
Chemical weapon designation
Chemical weapon proliferation
Chemical weapons in the Rif War
Chemically Assisted Degradation of PolymersChemically Imbalanced
Chemically strengthened glass
Chemicals (band)
Chemicals Convention, 1990Chemicals React
ChemicrazyChemidex
Chemie Grunenthal of Stolberg-am-Rhein
Chemigation valve
Chemikal Underground
Chemilla
ChemilliChemillyChemilly, Allier
Chemilly, Haute-SaôneChemilly-sur-SereinChemilly-sur-Yonne
ChemilléChemillé-sur-DêmeChemillé-sur-Indrois
Chemiluminescence
CheminChemin-d'Aisey
Chemin Craig
Chemin Vert (Paris Métro)
Chemin d'Aylmer
Chemin de CocaigneChemin de Fer
Chemin de Fer de La Mure
Chemin de Fer de Paris à Orléans
Chemin de Fer de Paris à Orléans et du Midi
Chemin de Fer de l'État
Chemin de Fer de la Baie de SommeChemin de Fer des Côtes-du-Nord
Chemin de Fer du Blanc-ArgentChemin de Fer du CambrésisChemin de Fer du Finistère
Chemin de Fer du MidiChemin de Fer du Nord
Chemin de fer Aigle-LeysinChemin de fer Aigle-Ollon-MontheyChemin de fer Aigle-Ollon-Monthey-Champery
Chemin de fer Aigle-Sepey-DiableretsChemin de fer Arnaud
Chemin de fer Bex-Villars-BretayeChemin de fer Bière-Apples-Morges
Chemin de fer Châtel-St-Denis-Bulle-Montbovon
Chemin de fer Châtel-St-Denis-PalézieuxChemin de fer Glion-Rochers-de-NayeChemin de fer Les Avants-Sonloup
Chemin de fer Monthey-Champéry-MorginsChemin de fer Montreux-Glion
Chemin de fer Montreux-Glion-Rochers-de-NayeChemin de fer Nyon-St-Cergue-Morez
Chemin de fer Yverdon - Ste-Croix
Chemin de fer de Petite Ceinture
Chemin de fer du Montenvers
Chemin de fer funiculaire Territet-Glion
Chemin de fer funiculaire Vevey-Chardonne-Mont Pèlerin
Chemin des Dames
Chemin des Révoires
Cheminas
CheminformaticsCheminiCheminon
CheminotChemins De Terre
Chemins de Fer Luxembourgeois
Chemins de Fer Québec-Gatineau
Chemins de Fer de ProvenceChemins de Fer de l'Ouest
Chemins de Fer du CalvadosChemins de Fer du Morbihan
Chemins de fer Fribourgeois Gruyère-Fribourg-MoratChemins de fer de Corse
Chemins de fer de Paris à Lyon et à la MéditerranéeChemins de fer de l'Est
Chemins de fer du Jura
Chemins de fer électriques VeveysansChemins de fer électriques de la GruyèreCheminée du Front de Seine
Chemiosmosis
Chemirani Ensemble

Previous page (Chelsia wilson) | Next page (Chemiré)



BUILD YOUR WEB SITE WITH www.DomainsUAE.com